Temperature
ReMoni's wireless temperature sensors offer easy monitoring for heating systems, optimize energy use, and detect inefficiencies in real-time. They install non-invasively, and TempMoniDC upgrades analog sensors for wireless communication, providing valuable temperature insights across applications.
TempMoniSpot

TempMoniSpot is a clamp-on sensor designed for temperature monitoring and surveillance.
TempMoniSpot is a wireless sensor, which measures temperature and can be used for surveillance and alarm setting in fx heating systems. It can help identify if the cooling is too low, leading to transmission losses, causing waste of resources.
Features
- Monitor temperature and gain further insight in operations and performance of systems.
- Wireless sensor with 3 measuring points: 2 fixed probes for mounting on the outside of the heating pipes and 1 internal sensor.
- Easy and non-invasive installation, as the sensor is clamped-on the outside of the pipe, without any damage to the installation.
- Enables setting alarms, for easier surveillance.
- Powered by the battery with 15 years lifetime.
- It provides overview of current temperature data and temperature patterns over time.

Use cases
TempMoniSpot is an ideal solution to monitor and track temperature changes in systems, pipes, rooms etc., to optimize performance, improve system understanding, and reuduce waste.
- Temperature measurements: Measurement of supply and return temperatures on district heating installations, natural gas boilers, and heat pumps. Also, measurement of domestic hot water temperature and coolant.
- Monitoring: Monitoring the temperature of cooling systems/chillers as well as refrigerated and freezer rooms provides a clear picture of whether the desired temperature is maintained or if there is efficiency in reaching the correct temperature
- Ventilation systems: Measurement on both the intake and exhaust sides, temperature measurement on heating surfaces, and room temperature.
- Seap & burst leakage and water wastage: With temperature measurements on cold water pipes and other water lines, seap leakage, burst leakage and water wastage can be detected. This helps prevent major damage and costly consumption.
Further insight
FAQ
When a temperature sensor reads out negative -55 degrees, this should be read as an error code. This means that the temperature probe is damaged or disconnected.
Above is an example where both external probes are damaged.
Solution:
TempMoniSpot
Replaced with a new sensor. As the housing is glued together, it is not possible to replace the probes.
TempMoniDC
Replace the damaged probe. New probes can be purchased at our Webshop.
NB: Feel free to send defective sensors back to ReMoni so that it can be safely disposed of.
TempMoniDC

TempMoniDC provides a unique opportunity to collect temperature data and upgrade analog sensors with wireless communication for data collection.
TempMoniDC is a solution ideal for temperature measuring and allowing to connect with compatible analog sesnors to communicate the collected data wirelessly to the cloud platform. Accordingly, it gives analog sensors an opportunity to wrelessly communicate data.
Features
- Combination of 7 channels with 3 temperature and 4 analog signals (VDC).
- Collected data stored and accessible in the ReCalc cloud platform.
- Receives signals at -24 to 24 VDC.
- The 4 analog signals allows to upgrade compatible analog sensors with wireless communication.
- Quick and easy installation.
- No damage to current installations or analog sensors.
- Easy to replace.

Use cases
TempMoniDC is ideal for monitoring and tracking temperature data as well as upgrading compatible analog sensors with wireless communication for thorough data collection.
- Data from analog sensors: Multiple analog sensors and devices send a VDC signal that can be detected with TempMoniDC, such as pressure sensors, PLCs with analog output, DC motor controllers, etc.
- Temperature measurements: Measurement of supply and return temperatures on district heating installations, natural gas boilers, and heat pumps. Also, measurement of domestic hot water temperature and coolant.
- Monitoring: Monitoring the temperature of cooling systems/chillers as well as refrigerated and freezer rooms provides a clear picture of whether the desired temperature is maintained or if there is efficiency in reaching the correct temperature
- Ventilation systems: Measurement on both the intake and exhaust sides, temperature measurement on heating surfaces, and room temperature.
- Water wastage: Measurement on both the supply and exhaust sides, temperature measurement on heating elements, and room temperature.
Further insight
When a temperature sensor reads out negative -55 degrees, this should be read as an error code. This means that the temperature probe is damaged or disconnected.
Above is an example where both external probes are damaged.
Solution:
HeatMoniSpot, FlowMoniEnergy, TempMoniSpot or FlowMoniSpot
Replaced with a new sensor. As the housing is glued together, it is not possible to replace the probes.
TempMoniDC
Replace the damaged probe. Contact us to get probes replaced.
NB: Feel free to send defective sensors back to ReMoni so that it can be safely disposed of.